Cardiac Resynchronization Therapy - CAM 647

Description
General Information

  • It is an expectation that all patients receive care/services from a licensed clinician. All appropriate supporting documentation, including recent pertinent office visit notes, laboratory data, and results of any special testing must be provided. If applicable: All prior relevant imaging results and the reason that alternative imaging cannot be performed must be included in the documentation submitted. 
  • Where a specific clinical indication is not directly addressed in this guideline, medical necessity determination will be made based on widely accepted standard of care criteria. These criteria are supported by evidence-based or peer-reviewed sources such as medical literature, societal guidelines, and state/national recommendations.
  • The guideline criteria in the following sections were developed utilizing evidence-based and peer-reviewed resources from medical publications and societal organization guidelines as well as from widely accepted standard of care, best practice recommendations.

Purpose
This guideline describes the medical necessity for cardiac resynchronization therapy (CRT). Indications for CRT for patients are based upon left ventricular (LV) ejection fraction (LVEF), QRS duration, New York Heart Association (NYHA) functional class (presence or absence of symptoms) and need for ventricular pacing regardless of etiology (ischemic or non-ischemic cardiomyopathy).   (1)

Clinical Reasoning
All criteria are substantiated by the latest evidence-based medical literature. To enhance transparency and reference, Appropriate Use (AUC) scores, when available, are diligently listed alongside the criteria.

This guideline first defaults to AUC scores established by published, evidence-based guidance endorsed by professional medical organizations. In the absence of those scores, we adhere to a standardized practice of assigning an AUC score of 6. This score is determined by considering variables that ensure the delivery of patient-centered care in line with current guidelines, with a focus on achieving benefits that outweigh associated risks. This approach aims to maintain a robust foundation for decision-making and underscores our commitment to upholding the highest standards of care. (2–6)

INDICATIONS FOR CARDIAC RESYNCHRONIZATION THERAPY (CRT)
Cardiomyopathy

NOTE: The following indications only apply to patients:

  • Who have been on guideline-directed medical therapy (GDMT) for 3 months or
  • Who have been on GDMT and are 40 days after myocardial infarction (MI), or
  • With implantation of pacing or defibrillation device for special indications (class indicates NYHA functional class)

Class I Through Class IV   (1,7)

  • Ischemic cardiomyopathy, LVEF ≤ 35%, QRS ≥ 150 ms, left bundle branch block (LBBB), Sinus Rhythm (AUC Score 7-9)
  • Nonischemic cardiomyopathy, LVEF ≤ 35%, QRS ≥ 150 ms, LBBB, Sinus Rhythm (AUC Score 7-9)

Class II Through Class IV   (1,7)

  • Ischemic and non-ischemic cardiomyopathy, LVEF ≤ 35%, QRS 120-149 ms, LBBB, Sinus Rhythm (AUC Score 7)
  • Ischemic and non-ischemic cardiomyopathy, LVEF ≤ 35%, QRS ≥ 150 ms, non-LBBB (AUC score 6)
  • Nonobstructive hypertrophic cardiomyopathy (HCM), LVEF < 50%, LBBB, CRT therapy for symptom reduction

Class III Through Class IV (1,8)

  • Ischemic and non-ischemic cardiomyopathy, LVEF ≤ 35%, QRS ≥ 150 ms, non-LBBB, Sinus Rhythm (AUC Score 7)

Special Circumstances when CRT ICD may be implanted after < 3 months GDMT

  • Criteria are met, based on a pacing indication, for a non-elective implantable cardioverter defibrillator (ICD) or pacemaker and in the face of the low likelihood of improvement in symptoms and adequate recovery of LVEF, despite less than 3 months GDMT for heart failure or < 40 days post myocardial infarction or 3 months post revascularization, criteria for CRT are otherwise met. This avoids a second implantation procedure within less than 3 months (1,9)

Special Situations: Independent/Regardless of NYHA Heart Failure Class

  • Patients with an indication for ventricular pacing, a LVEF ≤ 50%, and high degree atrioventricular (AV) block or are expected to be paced more than 40% of the time; this includes patients with atrial fibrillation (1,8)
  • Patients with atrial fibrillation and LVEF ≤ 35% who require ventricular pacing or otherwise meet CRT criteria; AND AV nodal ablation or pharmacologic rate control will result in nearly 100% ventricular pacing with CRT (7)
  • For patients with atrial fibrillation and LVEF≤ 50%, if a rhythm control strategy fails and ventricular rates remain rapid despite medical therapy, atrioventricular nodal ablation with implantation of a CRT device is reasonable (7)
  • As CRT has not been studied in transthyretin amyloid cardiomyopathy (ATTR-CM), those with heart failure with reduced ejection fraction (HFrEF) should follow guidelines for Class II-Class IV indications

Not Indicated

  • NYHA class I or II and non-LBBB pattern with QRS duration < 150 ms, (1) except as in Special Situations section above
  • NYHA class I through IV with QRS duration < 120 ms (1)
  • Comorbidities and/or frailty expected to limit survival with good functional capacity to <1 year (1,7)
  • Active bloodstream infection
  • Reversible causes are present such as toxic-, metabolic- or tachycardia-mediated cardiomyopathy,  require reassessment once the situation is corrected
  • Cardiogenic shock or symptomatic hypotension while in stable baseline rhythm

Adult Congenital Heart Disease (CHD)
Class I Through Class IV

  • Systemic ventricle with EF ≤ 35%, intrinsic narrow QRS complex, and undergoing new device placement or replacement with anticipated requirement for significant (> 40%) ventricular pacing (AUC Score 7-8) (10)
  • Systemic ventricle with EF > 35%, intrinsic narrow QRS complex, and undergoing new device placement or replacement with anticipated requirement for significant (> 40%) ventricular pacing (AUC Score 6) (10)
  • Any CHD, regardless of specific ejection fraction, with progression of systolic systemic ventricular dysfunction and/or ventricular dilation, and who are undergoing other cardiac surgery, (particularly if thoracotomy is anticipated to be needed for LV pacing), with a QRS complex ≥ 150 ms (AUC Score 6) (10)

Class II Through Class IV

  • Systemic LVEF ≤ 35%, sinus rhythm and wide QRS complex ≥ 150 ms (10)
  • Any CHD, wide QRS complex ≥ 150 ms due to a complete RBBB, with a severe sub-pulmonary right ventricle (RV) dysfunction and dilatation despite interventions to decrease RV volume overload (10)
  • Patients with single ventricle or systemic right ventricle with an LVEF ≤ 35% with QRS complexes ≥ 120 ms with either RBBB or LBBB morphology (10)

Class IV

  • Severe ventricular dysfunction, and would otherwise be candidates for heart transplantation or mechanical circulatory support (10)

Not Indicated

  • Patients whose co-morbidities and/or frailty limit survival with good functional capacity to < 1 year (10)
  • Patients with a narrow QRS complex (< 120 ms) without major electrical activation delay within the failing ventricle (10)

SUMMARY OF EVIDENCE
2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure (7)

Study Design: This document is a clinical practice guideline for the management of heart failure, developed by the American College of Cardiology/American Heart Association/Heart Failure Society of America Joint Committee on Clinical Practice Guidelines. It is based on a comprehensive literature search conducted from May 2020 to December 2020, including studies, reviews, and other evidence from human subjects published in English.

Target Population: The guideline is intended for clinicians to prevent, diagnose, and manage patients with heart failure. It provides patient-centric recommendations for the treatment of heart failure, aiming to improve quality of care and align with patients' interests.

Key Factors: The guideline includes recommendations for the prevention, diagnosis, and management of heart failure, based on contemporary evidence. It covers various aspects such as stages of heart failure, classification by left ventricular ejection fraction, diagnostic algorithms, epidemiology, causes, initial and serial evaluation, use of biomarkers, genetic evaluation, cardiac imaging, invasive evaluation, remote monitoring, exercise and functional capacity testing, risk scoring, and management strategies for different stages of heart failure.

 

Arrhythmias in congenital heart disease (10)

Study Design: This document is a position paper on arrhythmias in congenital heart disease, developed by the European Heart Rhythm Association, Association for European Pediatric and Congenital Cardiology, and the European Society of Cardiology Working Group on Grown-up Congenital Heart Disease, endorsed by HRS, PACES, APHRS, and SOLAECE. It is based on a detailed literature review and expert consensus.

Target Population: The position paper addresses arrhythmias in patients with congenital heart disease, focusing on young adults with congenital heart defects who suffer from arrhythmias due to the underlying defect or as a sequela of interventional or surgical treatment.

Key Factors: The paper discusses the management of arrhythmias in congenital heart disease, including pharmacological treatment, catheter ablation, and device therapy. It highlights the importance of understanding the individual pathological anatomy and physiology, as well as the natural history and long-term prognosis of patients. The document covers various types of arrhythmias, their substrates, work-up, acute assessment, collaboration between specialists, general assessment, imaging requirements, specific arrhythmia types, and management strategies.

 

ACC/AHA/ASE/HFSA/HRS/SCAI/SCCT/SCMR 2025 Appropriate Use Criteria for Implantable Cardioverter-Defibrillators, Cardiac Resynchronization Therapy, and Pacing  (1)

Study Design: This document is an appropriate use criteria (AUC) for implantable cardioverter-defibrillators (ICD), cardiac resynchronization therapy (CRT), and pacing, developed by the American College of Cardiology Solution Set Oversight Committee, American Heart Association, American Society of Echocardiography, Heart Failure Society of America, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, and Society for Cardiovascular Magnetic Resonance. It is based on a comprehensive review of common clinical scenarios and expert consensus.

Target Population: The AUC document addresses patients who are candidates for ICD, CRT, and pacing therapies, including those with heart failure, genetic conditions, structural heart disease, and other related conditions.

Key Factors: The document provides a detailed review of 335 clinical scenarios related to ICD, CRT, and pacing, including secondary prevention, primary prevention, comorbidities, generator replacement, dual-chamber ICD, totally subcutaneous ICD, CRT, LVAD, heart transplantation, cardiac contractility modulation, leadless pacing, and conduction system pacing. It categorizes the scenarios as "Appropriate," "May Be Appropriate," or "Rarely Appropriate" based on the potential benefits and risks of device implantation.

 

Analysis of evidence
Shared Findings (1,7,10)

  • Effectiveness: All three documents recognize the effectiveness of CRT in managing heart failure and arrhythmias. They emphasize the importance of CRT in improving patient outcomes, particularly in those with reduced ejection fraction and heart failure symptoms.
  • Patient Selection: The importance of selecting appropriate patients for CRT is highlighted across all documents. They stress the need for careful evaluation of patient characteristics, including ejection fraction, heart failure symptoms, and arrhythmia history.
  • Guideline Recommendations: The documents provide guideline-based recommendations for CRT, ensuring that clinicians have access to evidence-based practices for managing heart failure and arrhythmias

Conclusion (1,7,10)

In summary, these articles collectively provide a robust framework for managing various cardiovascular conditions, each contributing unique insights and recommendations tailored to specific patient populations and clinical scenarios.

BACKGROUND
CRT, which paces the left and right ventricle in rapid sequence, also known as biventricular pacing, improves coordination of left ventricular contraction in the presence of a wide QRS complex in systolic heart failure, by simultaneously pacing the interventricular septum and the left lateral wall.

CRT improves cardiac function and quality of life, and it decreases cardiac events and mortality among appropriately chosen patients. In the proper patient population, improved survival in patients with CRT can be greater than that provided by implantable cardioverter-defibrillator (ICD) insertion alone.

Guiding principles in the consideration of CRT:

  • NYHA class is an important qualifying factor, with candidacy based on functional class, EF, and QRS duration
  • Bundle branch block or intraventricular conduction delay should be persistent, not rate related (1)
  • GDMT should have been in place continuously for at least 3 months after initiation of therapy for cardiomyopathy or 40 days post myocardial infarction to allow recovery of LVEF. This 3-month time period is “reset” if a revascularization is performed in the interim. Reversible causes (e.g., ischemia) should be excluded (7)
  • The patient should have expected survival with a reasonably good functional status for more than 1 year   (1)

Definitions
NYHA Functional Classification for Heart Failure

The New York Heart Association (NYHA) classes of heart failure is the most commonly used system to classify stages of heart failure. (11) Classes are based on physical activity limitations.

  • Class I: No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, heart palpitations, or shortness of breath
  • Class II: Slight limitation on physical activity. Comfortable at rest but ordinary physical activity results in fatigue, heart palpitations, shortness of breath or chest pain
  • Class III: Marked limitation on physical activity. Comfortable at rest but less than ordinary activity causes fatigue, heart palpitations, shortness of breath or chest pain
  • Class IV: Symptoms of heart failure at rest. Any physical activity increases discomfort

Heart Block (12)

  • First-degree atrioventricular (AV) block:
    • P waves associated with 1:1 AV conduction and a PR interval > 200 ms
  • Second-degree AV block:
    • P waves with a constant rate (< 100 bpm) where AV conduction is present but not 1:1
      • Mobitz type I
        • P waves with a constant rate (< 100 bpm) with a periodic single nonconducted P wave associated with P waves before and after the nonconducted P wave with inconstant PR intervals
      • Mobitz type II
        • P waves with a constant rate (< 100 bpm) with a periodic single nonconducted P wave associated with other P waves before and after the nonconducted P wave with constant PR intervals (excluding 2:1 AV block)
      • 2:1 AV block
        • P waves with a constant rate (or near constant rate because of ventriculophasic sinus arrhythmia) rate (< 100 bpm) where every other P wave conducts to the ventricles
      • Advanced, high-grade or high-degree AV block
        • ≥ 2 consecutive P waves at a constant physiologic rate that do not conduct to the ventricles with evidence for some AV conduction
  • Third-degree AV block:
    • Complete heart block – no evidence of AV conduction

Guideline-Directed (or Optimal) Medical Therapy in Heart Failure  (7)

Documentation of GDMT must include the doses and the date of initiation of each medication and must reflect 90 days of therapy since the initiation of the maximal dose administered. If a drug or class of drug is omitted, an explanation for its omission must be provided (intolerance, hypotension, bradycardia, or barriers to access are acceptable explanations). Notes must reflect adequate control of vital signs (BP < 140/90, HR < 100):

  • Angiotensin converting enzyme inhibitor (ACE-I), angiotensin receptor blocker (ARB), or combined angiotensin receptor inhibitor and neprilysin inhibitor (ARNI)
  • Beta blocker
  • Addition of an aldosterone antagonist, provided eGFR is ≥ 30 ml/min/1.73 m2 and K+ < 5.0, NYHA class II-IV
  • SGLT2 Inhibitor (e.g., dapagliflozin, empagliflozin)

NOTE: GDMT requirement does not apply when CRT is indicated for secondary prevention of VT/VF, or in conditions in which the indication is not dependent on the left ventricular ejection fraction.

Other options/considerations for GDMT (7)

  • Addition of loop diuretic for all NYHA class II – IV patients
  • Addition of hydralazine and nitrate for persistently symptomatic African Americans, NYHA class III-IV
  • Not required, but may be considered: Ivabradine for NYHA class II – III, when a beta blocker has failed to reduce a sinus rate to < 70 bpm. Ivabradine listed as a class IIa recommendation, while others are class I recommendations. CRT trials antedated routine use of Ivabradine.

AUC Score

A reasonable diagnostic or therapeutic procedure can be defined as that for which the expected clinical benefits outweigh the associated risks, enhancing patient care and health outcomes in a cost-effective manner. (5)

  • Appropriate Care- Median Score 7-9
  • May be Appropriate Care- Median Score 4-6
  • Rarely Appropriate Care- Median Score 1-3

Acronyms/Abbreviations

ACE-I: Angiotensin converting enzyme inhibitor

ARB: Angiotensin receptor blocker

ARNI: Combined angiotensin receptor inhibitor and neprilysin inhibitor

ATTR-CM: Transthyretin Amyloid Cardiomyopathy

AV: Atrioventricular

CAD: Coronary artery disease, same as ischemic heart disease

CHD: Congenital heart disease

CRT: Cardiac resynchronization therapy (also known as biventricular pacing)

EF: Ejection Fraction

eGFR: Estimated glomerular filtration rate

GDMT: Guideline-Directed Medical Therapy

HCM: Hypertrophic Cardiomyopathy

HF: Heart failure

HFrEF: Heart failure with reduced ejection fraction

ICD: Implantable cardioverter-defibrillator

LBBB: Left bundle branch block

LV: Left ventricular/left ventricle

LVEF: Left ventricular ejection fraction

MI: Myocardial infarction

ms: Milliseconds

NYHA: New York Heart Association

RBBB: Right bundle branch block

RV: Right ventricle     

References

1.       Russo AM, Desai MY, Do MM, et al. ACC/AHA/ASE/HFSA/HRS/SCAI/SCCT/SCMR 2025 Appropriate Use Criteria for Implantable Cardioverter-Defibrillators, Cardiac Resynchronization Therapy, and Pacing. J Am Coll Cardiol. Published online January 2025. doi:10.1016/j.jacc.2024.11.023

2.       Bonow RO, Douglas PS, Buxton AE, et al. ACCF/AHA Methodology for the Development of Quality Measures for Cardiovascular Technology. J Am Coll Cardiol. 2011;58(14):1517-1538. doi:10.1016/j.jacc.2011.07.007

3.       Fitch Kathryn, Bernstein SJ, Aguilar MD, et al. The RAND/UCLA Appropriateness Method User’s Manual. RAND.; 2001. Accessed October 8, 2024. https://www.rand.org/pubs/monograph_reports/MR1269.html

4.       Hendel RC, Patel MR, Allen JM, et al. Appropriate Use of Cardiovascular Technology: 2013 ACCF appropriate use criteria methodology update. J Am Coll Cardiol. 2013;61(12):1305-1317. doi:10.1016/j.jacc.2013.01.025

5.       Hendel RC, Lindsay BD, Allen JM, et al. ACC Appropriate Use Criteria Methodology: 2018 Update. J Am Coll Cardiol. 2018;71(8):935-948. doi:10.1016/j.jacc.2018.01.007

6.       Patel MR, Spertus JA, Brindis RG, et al. ACCF Proposed Method for Evaluating the Appropriateness of Cardiovascular Imaging. J Am Coll Cardiol. 2005;46(8):1606-1613. doi:10.1016/j.jacc.2005.08.030

7.       Heidenreich PA, Bozkurt B, Aguilar D, et al. 2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure. J Am Coll Cardiol. 2022;79(17):e263-e421. doi:10.1016/j.jacc.2021.12.012

8.       McDonagh TA, Metra M, Adamo M, et al. 2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure. Eur Heart J. 2021;42(36):3599-3726. doi:10.1093/eurheartj/ehab368

9.       Kusumoto FM, Calkins H, Boehmer J, et al. HRS/ACC/AHA expert consensus statement on the use of implantable cardioverter-defibrillator therapy in patients who are not included or not well represented in clinical trials. Circulation. 2014;130(1):94-125. doi:10.1161/CIR.0000000000000056

10.     Hernández-Madrid A, Paul T, Abrams D, et al. Arrhythmias in congenital heart disease: A position paper of the European Heart Rhythm Association (EHRA), Association for European Paediatric and Congenital Cardiology (AEPC), and the European Society of Cardiology (ESC) Working Group on Grown-up Congenital heart disease, endorsed by HRS, PACES, APHRS, and SOLAECE. Europace. 2018;20(11):1719-1720. doi:10.1093/europace/eux380

11.      American Heart Association. Classes and Stages of Heart Failure. American Heart Association. June 7, 2023. Accessed October 22, 2024. https://www.heart.org/en/health-topics/heart-failure/what-is-heart-failure/classes-of-heart-failure

12.      Kusumoto FM, Schoenfeld MH, Barrett C, et al. 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. 2019;74(7):e51-e156. doi:https://doi.org/10.1016/j.jacc.2018.10.044

 

Coding Section

Code Number Description
 

33224

Insertion of pacing electrode, cardiac venous system, for left ventricular pacing, with attachment to previously placed pacemaker or implantable defibrillator pulse generator (including revision of pocket, removal, insertion, and/or replacement of existing generator)

 

33231

Insertion of implantable defibrillator pulse generator only; with existing multiple leads

 

33241

Removal of implantable defibrillator pulse generator only

 

33249

Insertion or replacement of permanent implantable defibrillator system, with transvenous lead(s), single or dual chamber

 

+33225

Insertion of pacing electrode, cardiac venous system, for left ventricular pacing, at time of insertion of implantable defibrillator or pacemaker pulse generator (eg, for upgrade to dual chamber system) (List separately in addition to code for primary procedure)

 

Procedure and diagnosis codes on Medical Policy documents are included only as a general reference tool for each Policy. They may not be all-inclusive.

This medical policy was developed through consideration of peer-reviewed medical literature generally recognized by the relevant medical community, U.S. FDA approval status, nationally accepted standards of medical practice and accepted standards of medical practice in this community, and other nonaffiliated technology evaluation centers, reference to federal regulations, other plan medical policies and accredited national guidelines.

"Current Procedural Terminology © American Medical Association. All Rights Reserved" 

History From 2026 Forward

11/01/2026 New Policy
Complementary Content