Implantable Cardioverter Defibrillator - CAM 654

Description
General Information

  • It is an expectation that all patients receive care/services from a licensed clinician. All appropriate supporting documentation, including recent pertinent office visit notes, laboratory data, and results of any special testing must be provided. If applicable: All prior relevant imaging results and the reason that alternative imaging cannot be performed must be included in the documentation submitted. 
  • Where a specific clinical indication is not directly addressed in this guideline, medical necessity determination will be made based on widely accepted standard of care criteria. These criteria are supported by evidence-based or peer-reviewed sources such as medical literature, societal guidelines, and state/national recommendations.
  • The guideline criteria in the following sections were developed utilizing evidence-based and peer-reviewed resources from medical publications and societal organization guidelines as well as from widely accepted standard of care, best practice recommendations.

Purpose
Indications for determining medical necessity for an implantable cardiac defibrillator (ICD). Implantable cardioverter defibrillators (ICDs) are indicated for the treatment of life-threatening ventricular tachycardia and ventricular fibrillation. All indications are predicated on a meaningful life expectancy of greater than one year if the ICD is implanted.

Special Note
Providers must involve patients in a shared decision-making process involving reason(s) for, as well as the type of procedure(s) that could be used including continued conservative treatment, and their potential outcomes. The possibility of continued symptoms despite therapy as well as the need for subsequent procedures must also be discussed. This process must be reflected in notes provided. 

Clinical Reasoning
All criteria are substantiated by the latest evidence-based medical literature. To enhance transparency and reference, Appropriate Use (AUC) scores, when available, are diligently listed alongside the criteria.

This guideline first defaults to AUC scores established by published, evidence-based guidance endorsed by professional medical organizations. In the absence of those scores, we adhere to a standardized practice of assigning an AUC score of 6. This score is determined by considering variables that ensure the delivery of patient-centered care in line with current guidelines, with a focus on achieving benefits that outweigh associated risks. This approach aims to maintain a robust foundation for decision-making and underscores our commitment to upholding the highest standards of care. (1–5)

eligibility for Implantable cardioverter-defibrillator (icd) implantation

Patient eligibility for an ICD presumes all the following:

  • Anticipated reasonable quality of life for ≥ 1-year post implantation
  • Patient’s ability to live with a shock-delivering device that requires management
  • Absence of a completely reversible cause that led to ventricular arrhythmia (VA) for which an ICD is being considered
  • Completion of ≥ 3 months of guideline-directed medical therapy (GDMT) for heart failure (HF), unless an intervening indication for pacemaker implantation arises or in special circumstances which are exempt from GDMT
  • ICD indications are present in most scenarios in which cardiac resynchronization therapy (CRT) is appropriate
  • With respect to coronary artery disease (CAD), if no revascularization is planned, there must be documentation that there is:
    • No evidence for epicardial coronary lesions measuring > 70% (non-left main) or <50% left main or no evidence for ischemia by fractional flow reserve or perfusion imaging
    • In the presence of severe coronary artery disease that the patient is not a candidate for revascularization due to the nature of the disease (i.e., diffuse and not amenable to intervention) (6)
  • With respect to CAD, if coronary revascularization is planned, ICD implantation may not be performed prior to intervention in an effort to circumvent the 3-month waiting period (6)

NOTE: Guidelines for the pediatric population are extrapolated from the adult population due to a lack of relevant trials.

INDICATIONS FOR ICD IMPLANTATION
Ischemic Heart Disease (CAD) (6,7)
Primary Prevention of Sudden Cardiac Death (SCD)/Prophylactic ICD Implantation

  • Post- Acute myocardial infarction (MI) (≤ 40 days)
    • Left ventricular ejection fraction (LVEF) ≤ 30%
      • Asymptomatic nonsustained ventricular tachycardia (NSVT) (4 or more days post MI), and electrophysiologic study (EPS) with sustained inducible ventricular tachycardia (VT) after revascularization (within 40 days of MI) (AUC Score 7) or without revascularization (AUC Score 8)
    • LVEF 31-40%
      • Asymptomatic NSVT (4 or more days post MI) and EPS with sustained inducible VT after revascularization (within 40 days of MI) (AUC Score 7)
    • Pre-existing Chronic Cardiomyopathy
      • LVEF ≤ 30% due to old infarction, New York Heart Association (NYHA) class I (AUC Score 7)
      • LVEF ≤ 35% due to old infarction or nonischemic causes, NYHA class II or III (AUC Score 8)
    • Need for Guideline-Directed Pacemaker Therapy and LVEF ≤ 35% (AUC Score 7)
  • Post MI (> 40 days)
    • With Ischemic Cardiomyopathy
      • No recent PCI/CABG
        • NYHA Class I
          • LVEF ≤ 30% (AUC Score 8)
          • LVEF 31% - 35% (AUC Score 7)
          • LVEF 36% - 40%, asymptomatic NSVT and EPS with inducible sustained VT/VF (AUC Score 7)
        • NYHA Class II-III
          • LVEF ≤ 35 % (AUC Score 9)
          • LVEF 36% - 40%, asymptomatic NSVT and EPS with inducible sustained VT/VF (AUC Score 8)
      • Recent percutaneous coronary intervention (PCI) or coronary artery bypass surgery (CABG) (within past 3 months)
        • NYHA Class I, II, or III
          • LVEF ≤ 35% on GDMT (for at least 3 months) and pre-existing cardiomyopathy (AUC Score 7)
          • LVEF ≤ 35% and need for permanent pacemaker post revascularization (AUC Score 8)
  • Without recent MI
    • With ischemic cardiomyopathy, revascularization not indicated
      • GDMT < 3 months
        • LVEF ≤ 35%, NSVT and EPS with inducible sustained VT (AUC Score 8)
      • GDMT ≥ 3 months
        • LVEF ≤ 35% (AUC Score 9)

Secondary Prevention of SCD

  • Hemodynamically unstable or sustained VT, ventricular fibrillation (VF) or polymorphic VT
    • During or within 48 hours of acute MI
      • Not amenable to revascularization (AUC Score 7)
      • Post-elective revascularization (AUC Score 7)
    • No recent MI and no recent revascularization
      • No identifiable transient and completely reversible causes, and no need for revascularization (AUC Score 8-9)
      • Significant CAD but no revascularization performed (AUC Score 8-9)
      • Significant CAD and incomplete revascularization after cardiac arrest (AUC Score 7-9)
      • Significant CAD and complete revascularization performed after cardiac arrest, if LVEF is ≤ 35% (AUC Score 7)
  • Unexplained syncope, with inducible VF or sustained VT at electrophysiological study, LVEF 36-49% and prior MI (not acute) (AUC Score 8)
  • Unexplained Syncope, with LVEF ≤ 35%, and prior MI (not acute) (AUC Score 8-9)
  • Sustained hemodynamically stable Monomorphic VT associated with structural heart disease
    • LVEF ≥ 36%
      • CAD and prior MI or Nonischemic Dilated Cardiomyopathy (AUC Score 7)
    • LVEF ≤ 35%
      • Bunde branch re-entry successfully ablated and Nonischemic Cardiomyopathy (AUC Score 7)
      • Nonischemic dilated cardiomyopathy with all inducible VTs successfully ablated (AUC Score 8)
      • CAD and prior MI or nonischemic dilated cardiomyopathy (AUC Score 9)

Nonischemic Cardiomyopathy (NICM) (6)
Primary Prevention of SCD/Prophylactic ICD Implantation

  • Lamin A/C gene mutation, with ≥ 2 risk factors from the following: NSVT, LVEF < 45%, male sex, missense mutation
  • Without recent MI
    • GDMT ≥ 3 months and any of the following:
      • LVEF≤ 35%; age < 85 years; any QRS duration (AUC Score 7-8)
      • LVEF≤ 35%; age > 85 years; any QRS duration, NYHA II-III (AUC Score 6)
    • LVEF >35% with LGE on MRI and NYHA II-III (AUC Score 6)
  • Chagas disease, even if on GDMT < 3 months, LVEF ≤ 35% (AUC Score 8)

Secondary Prevention of SCD

  • Unexplained syncope
    • With LVEF <50% and
      • Left ventricular noncompaction (AUC Score 7)
      • Hypertrophic cardiomyopathy (AUC Score 8)
    • With LVEF ≤ 35% and
      • Non-ischemic dilated cardiomyopathy (AUC Score 8)
      • Left ventricular noncompaction (AUC Score 8)
    • With arrhythmogenic right ventricular cardiomyopathy (AUC Score 7-8)
  • Hemodynamically unstable or sustained VT, polymorphic VT or VF, not due to a reversible cause (AUC Score 8-9)

Advanced Heart Failure & Transplantation (6,7)

  • In non-hospitalized patients with NYHA class IV who are candidates for cardiac transplantation or left ventricular assist device (LVAD)
  • In a patient with an LVAD, with sustained ventricular arrhythmias
  • In NYHA ambulatory class IV, with appropriate indications for CRT

Myocardial Diseases
Hypertrophic Cardiomyopathy (HCM) (6–9)

  • Previously documented cardiac arrest
  • Sustained VT (AUC Score 9)
  • Adult patients with HCM with at least 1 risk factor for SCD as follows (AUC Score 8):
    • Sudden death attributable to HCM in at least 1 first-degree relative who is ≤ 50 years of age 
    • LVH ≥ 30 mm
    • At least 1 recent (within 5 years) episode of syncope suspected by history to be arrhythmic (unlikely neurocardiogenic (vasovagal), especially occurring within 6 months of evaluation
    • LV apical aneurysm 
    • LV systolic dysfunction (EF < 50%)  
    • Pediatric patients with HCM with at least 1 risk factor for SCD as follows:
      • Unexplained syncope
      • LVH ≥ 30 mm
      • Nonsustained VT
      • Family history of HCM-related SCD
  • Structural cardiac disease with genetic arrhythmogenic cardiomyopathy (i.e. Lamin A/C mutation) and LVEF < 45% (AUC Score 7)

Cardiac Sarcoidosis

With one of the following (6,7,10) :

  • Cardiac arrest or documented sustained VT
  • VF/Hemodynamically unstable VT that is associated with other structural heart disease (AUC Score 9)
  • LVEF > 35% with inducible sustained VT/VF at electrophysiological testing
  • LVEF ≤ 35%
  • Syncope
  •  Scar on CMR or PET
  • Requires a permanent pacemaker

Giant-Cell Myocarditis (6)

  • VF/Hemodynamically unstable VT that is associated with other structural heart disease (AUC Score 8)

Neuromuscular Disorders

Including but not limited to Duchenne, Becker, Limb-girdle type 1B, Limb-girdle type 2C-2F, Limb-girdle type 2I, Myotonic type 1, Myotonic type 2, Emery-Dreifuss, or Facioscapulohumeral Muscular Dystrophy with one of the following (6,7) :

  • Primary and secondary prevention, with same indications as for NICM
  • Emery-Dreifuss or limb-girdle type I-B muscular dystrophy with progressive cardiac involvement


Arrhythmogenic Right Ventricular CardiomyopathyWith at least one of the following risk factors for SCD (6–8) :

  • Resuscitated sudden cardiac arrest
  • Sustained VT (AUC Score 9)
  • Right or left ventricular systolic dysfunction with an EF ≤ 35%
  • Syncope with documented or presumed ventricular arrhythmia

Channelopathies
Congenital Long QT Syndrome

With one of the following (AUC Score 9) (6,7) :

  • Sudden cardiac arrest
  • Sustained VT (AUC Score 9) or recurrent syncope when beta blocker is ineffective or not tolerated (AUC Score 7)
  • QTc > 500 ms on a beta blocker
  • Strong family history of SCD
  • High risk genotype

Brugada Syndrome and Spontaneous Type 1 Brugada Echocardiographic Pattern

With one of the following (6,7,9) :

  • Cardiac arrest
  • Documented sustained VT/VF (AUC Score 9)
  • Unexplained syncope (AUC Score 7-9)

Catecholaminergic Polymorphic VT

With one of the following (6,7) :

  • Sudden cardiac arrest
  • Syncope or sustained VT/VF (AUC Score 9)
  • Inducible VT or VF
  • Unexplained syncope with beta-blockers (AUC Score 7)
  • Not tolerating medical therapy or breakthrough nonsustained ventricular arrhythmias on medical therapy (AUC Score 8)

Early Repolarization ("J-wave Syndrome") or Short QT Syndrome

With one of the following (AUC Score 9) (6,7) :

  • Cardiac arrest
  • Sustained VA

Idiopathic Polymorphic VT/VF (6,7)

  • Cardiac arrest due to polymorphic VT or VF
  • Normal ventricular function and no family history or first-degree relative with sudden cardiac death (AUC Score 8-9)

Adult & Pediatric Congenital Heart Disease (CHD) (7,9,11)

  • Cardiac arrest due to VF or VT, or unstable VT, after exclusion of a reversible etiology
  • Symptomatic sustained VT, after hemodynamic and electrophysiologic evaluation
  • Systemic LVEF ≤ 35%, biventricular physiology, and NYHA class II or III on GDMT
  • Single or systemic RVEF < 35%, in the presence of an additional risk factor such as:
    • NSVT
    • Unexplained syncope
    • NYHA class II or III, despite GDMT
    • QRS duration ≥ 140 ms
    • Severe systemic AV valve regurgitation
  • Syncope of unknown origin in the presence of either at least moderate ventricular dysfunction or marked hypertrophy or inducible sustained VT or VF
  • Syncope and moderate or severe complexity CHD, with high clinical suspicion of VA
  • Non-hospitalized patients with CHD awaiting heart transplant (AUC Score 7)
  • Left ventricular non-compaction that meets same indications as NICM, including a familial history of SCD (AUC Score 8)

ICD Indications With Special Situations (6,7,12)

  • ICD implantation is appropriate in the setting of elevated troponin levels when ICD criteria have been met, and elevated troponin is deemed not due to a myocardial infarction

NOTE: In the following circumstances, CRT is likely to be the appropriate modality when it is anticipated that significant (> 40%) ventricular pacing will be required:

  • ICD criteria met, except for myocardial infarction within 40 days or revascularization within 3 months, but a non-elective permanent pacemaker (new or replacement) is required, and recovery of left ventricular function to LVEF > 35% is uncertain or not expected *
  • ICD criteria met, except NICM or ischemic cardiomyopathy has not had 3 months’ time for LVEF to improve on medical therapy, a non-elective permanent pacemaker is required, and recovery of LVEF is uncertain or not expected*
  • Patient met primary prevention criteria for an ICD prior to surgical coronary revascularization, and it is unlikely that LVEF will recover to > 35% despite a 90-day wait (permits placement of an epicardial LV lead)

* These indications avoid a second implantation procedure within less than 3 months

Subcutaneous ICD

Subcutaneous ICD may be used in any patient meeting the criteria for a transvenous device, with the following exceptions (6) :

  • Bradycardia requiring pacing
  • Anticipated need for Cardiac Resynchronization Therapy (CRT)
  • Anticipated need for anti-tachycardia pacing (ATP)
  • Anticipated need for pacing following termination of VT/VF

Additionally, subcutaneous ICD is often the modality of choice in patients with no or limited transvenous access and may be preferable for patients with an elevated risk of infection.

 

Indications for Device or lead replacement

NOTE: Guideline-directed medical therapy indications do not need to be met for replacement of an ICD pulse generator or lead system.

ICD Pulse Generator Replacement

  • Recent interrogation shows battery voltage in elective replacement indicator (ERI or ERT) range or end of life (EOL/EOS) indicator range (may differ by device type and manufacturer).
  • Replacement of the pulse generator may be performed if a manufacturer’s recall has been issued, regardless of battery status

NOTE: The indicator “less than 3 months” in the battery status report typically refers to the time to ERI/ERT. It denotes an indication for intensified follow-up. In selected cases (pacemaker-dependency, follow-up compliance issues) device replacement may be considered for safety concerns when this parameter is met.

Lead Replacement

  • Lead repositioning/replacement/removal may be performed when there is evidence of lead malfunctioning on recent interrogation or if a lead recall has been issued
  • Device pocket infection typically requires pulse generator and lead removal and replacement

Device Relocation

  • Repositioning/relocation of the skin pocket for the device may be performed in the presence of infection, the development of overlying skin erosion/tissue necrosis, if any other anatomical factor prevents the device from properly functioning, or if device migration has resulted in significant patient discomfort.

INDICATIONS FOR DEVICE UPGRADE
From Single Chamber to Dual Chamber/CRT Pacing

  • In patients with existing single chamber ICD who develop clinical indications for dual chamber pacing or resynchronization therapy, placement of additional leads and replacement of the existing pulse generator may be approved

From Right Ventricular Pacing to Biventricular Pacing (CRT)

  • In patients with an existing pacing device, when criteria for resynchronization therapy have been met and placement of a left ventricular lead is planned, the pulse generator should be upgraded to a CRT device.

Defibrillation threshold testing

  • Induction of VF for the purpose of establishing the efficacy of defibrillation and/or determining the defibrillation threshold may be undertaken at the time of device implantation and replacement.

Indications for Temporary Transvenous Pacemaker

  • At the discretion of the implanting physician, a temporary transvenous pacemaker may be placed at the time of initial lead placement or pulse generator change, when there is concern that an interruption in AV conduction may occur in response to the surgical procedure. Examples include pacemaker-dependent patients, patients with high grade AV Block, and patients with LBBB in whom lead placement my “bump” the right bundle branch, resulting in transient complete heart block.

Indications for Subclavian Venography and Ultrasound

  • At the discretion of the implanting physician, vascular access for lead placement may be aided by imaging the subclavian vein using ultrasound or venography. The latter is achieved by establishing venous access in the ipsilateral arm and injecting iodinated contrast, using fluoroscopy to identify the target vessel and guide entry with the needle and guidewire. (13)

 

BACKGROUND
Definitions 

  • Anatomically suitable lesion (6) : one where the appropriate intervention would have low risk, and a high probability of initial and long-term success (> 2 years) based on accepted lesion classifications such as TASC II or GLASS.
  • Ankle Brachial Index (ABI)
    • ABI Reference Ranges:
      • Abnormal: ≤ 0.90
      • Borderline: 0.91-0.99
      • Normal: 1.00-1.40
      • Rest pain: ≤ 0.40
      • Noncompressible: > 1.40
    (7) : The Ankle Brachial Pressure Index, known more commonly as an ABI, is performed using a doppler device and is calculated by dividing the resting systolic blood pressure at the dorsalis pedis and posterior tibial arteries by the systolic blood pressures in the arm and is expressed as a ratio. The ABI is the higher of the two measurements. Photoplethysmographic techniques to measure ABI are not an acceptable substitute for a doppler derived ABI. The ABI can be spurious if there is heavy arterial calcification making the blood pressures unrecordable or falsely elevated.
  • Chronic Limb Threatening Ischemia (CLTI) has replaced Critical Limb Ischemia (CLI) since the threat to limb viability in patients with PAD is not only related to ischemia but other factors such as infection, neuropathy, and general patient morbidities. Further, “critical” implies that treatment is urgent to avoid limb loss, while some patients can keep their legs for extended periods of time even in the absence of revascularization. CLTI is defined clinically by the presence of rest pain (see definition), gangrene, a nonhealing wound or ulceration lasting more than 2 weeks despite appropriate wound care. Infection may make invasive treatment more urgent. The Society for Vascular Surgery Lower Extremity Threatened Limb Classification System (WIfI) is helpful in defining CLTI and prognosticating indications for treatment and outcome. (11)
  • Claudication: a symptom complex of pain that begins with ambulation and that is relieved within a brief time by walking cessation. It will usually resume at the same distance walked. It is described by the intensity of discomfort, the distance walked, the duration of the walk and the impact that it has on quality of life (QOL) and activities of daily living (ADL). Claudication does not occur at rest. If left untreated, the natural history of claudication is slow progression, yet amputation is rare occurring in less than 5% of patients.
  • Clinically significant disease is such that it is likely causing ischemic symptoms or findings
  • Endovascular intervention: the treatment of vascular pathology with angioplasty, atherectomy, intravascular lithotripsy, drugs, stents or any such treatment performed from within the blood vessel and access from a remote site
  • Guideline Directed Medical Therapy (GDMT) includes recommendations for antiplatelet therapy, cilostazol (unless contraindicated or not tolerated), statins, glycemic and hypertension control, structured exercise program (see definition), smoking cessation including planning, counseling, or behavior modification and pharmacotherapy if needed. Duration should be for at least 12 weeks.
  • Physiologic studies include ABI, TBI, Toe pressures, TcPO2, PVR or Doppler tracings
  • Rest Pain: a distinct pain syndrome lasting more than 2 weeks, implying CLTI. It is defined as pain in the foot or toes aggravated by elevation and relieved by dependency. Nocturnal pain is not necessarily rest pain since there are other causes of pain at night. Rest pain does not usually imply the same urgency for treatment as gangrene or nonhealing wounds.
  • Structured exercise program is provider-directed and monitored. It involves walking to a pain threshold 3 times a week.
  • Toe Brachial Index is measured by dividing the highest brachial arm pressure by the pressure obtained from the first toe by any method. Unlike the ABI, the toe pressures are usually not affected by arterial calcification.

AUC Score

A reasonable diagnostic or therapeutic procedure can be defined as that for which the expected clinical benefits outweigh the associated risks, enhancing patient care and health outcomes in a cost-effective manner. (2)

  • Appropriate Care- Median Score 7-9
  • May be Appropriate Care- Median Score 4-6
  • Rarely Appropriate Care- Median Score 1-3

Acronyms/Abbreviations

ABI: Ankle Brachial Index

AR: Authorization Request

AUC: Appropriate use criteria

CLTI: Chronic limb Threatening ischemia

CPT: Current Procedural Terminology

CTA: Computed Tomography Angiography

DSA: Digital Subtraction Angiography

GDMT: Guideline directed medical therapy

GLASS: Global Anatomic Staging System

PAD: Peripheral artery disease

PSV: Peak Systolic Velocity

PTA: Percutaneous transluminal angioplasty

PVR: Pulse Volume Recording

TASC: Trans-Atlantic Inter-Society Consensus

TBI: Toe Brachial Index

TcPO2: Tissue partial pressure of O2

WIfI Classification: Wound, Ischemia, and Foot Infection

Guideline Directed Medical Therapy

Guideline directed medical therapy (GDMT) are outlined by joint American College of Cardiology (ACC)/American Heart Association (AHA) in cardiovascular clinical practice guidelines as Class I recommendation. These are maximally tolerated medications for a cardiovascular condition, when prescribed, have shown to improve healthcare outcomes such as survival along with significant reduction in major adverse cardiovascular events and hospitalization. For all recommended drug treatment regimens, the prescriber should confirm the dosage with product insert material and carefully evaluate for contraindications and interactions.

 

Summary of Evidence

ACC/AHA/SCAI/SIR/SVM 2018 Appropriate Use Criteria for Peripheral Artery Intervention  (6)

Study Design: This study involved the development of Appropriate Use Criteria (AUC) for peripheral artery intervention (PAI). The process included drafting patient scenarios, assumptions, and definitions based on published guidelines, trial data, and expert opinions. The scenarios were evaluated by an independent rating panel using a scoring scale from 1 to 9.

Target Population: The study focused on patients with peripheral artery disease (PAD) who may require revascularization treatments. This includes patients with renal artery stenosis, lower extremity disease, critical limb ischemia, asymptomatic artery disease, and secondary treatment options for lower extremity disease.

Key Factors:

Clinical Scenarios: 45 clinical scenarios with up to 6 intervention options per scenario were developed and categorized into 6 general sections.

Scoring: Each indication was scored as “Appropriate” (7 to 9), “May Be Appropriate” (4 to 6), or “Rarely Appropriate” (1 to 3).

Emphasis: Adherence to medical therapy was emphasized, with revascularization considered when medical therapy is insufficient.

Endovascular and Surgical Approaches: Both approaches were deemed appropriate in scenarios involving tissue loss or end organ compromise, with a tendency to select endovascular approaches.

 

2024 ACC/AHA/AACVPR/APMA/ABC/SCAI/SVM/SVN/SVS/SIR/VESS Guideline for the Management of Lower Extremity Peripheral Artery Disease (7)

Study Design: This document is the 2024 ACC/AHA/AACVPR/APMA/ABC/SCAI/SVM/SVN/SVS/SIR/VESS guideline for the management of lower extremity peripheral artery disease. It was developed by the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines in collaboration with several other organizations.

Target Population: The guidelines are intended for clinicians treating patients with lower extremity peripheral artery disease across its multiple clinical presentation subsets, including asymptomatic PAD, chronic symptomatic PAD, chronic limb-threatening ischemia, and acute limb ischemia.

Key Factors: The document provides comprehensive recommendations on the clinical assessment, diagnostic testing, medical therapy, preventive foot care, exercise therapy, revascularization techniques, management of chronic limb-threatening ischemia, and acute limb ischemia. It also addresses special considerations such as risk amplifiers, health disparities, and management of PAD in older patients.

 

The Society for Vascular Surgery Lower Extremity Threatened Limb Classification System: Risk stratification based on Wound, Ischemia, and foot Infection (WIfI) (11)

Study Design: This document introduces the Society for Vascular Surgery Lower Extremity Threatened Limb Classification System, known as WIfI (Wound, Ischemia, and foot Infection).

Target Population: The classification system is designed for patients with threatened lower extremities due to chronic ischemia, particularly those with diabetes and diabetic foot ulcers.

Key Factors: The WIfI system stratifies patients based on the severity of wounds, ischemia, and infection. It aims to provide a more precise description of disease burden and improve outcomes analysis for various therapies. The system includes four grades for each factor and uses a Delphi consensus process to estimate the risk of amputation and the benefit of revascularization.

 

Analysis of Evidence

Shared Conclusions

  • Importance of Revascularization: All three articles emphasize the critical role of revascularization in managing peripheral artery disease (PAD) and critical limb ischemia (CLI). They agree that revascularization, whether through open surgical or endovascular procedures, is essential for improving limb salvage and patient outcomes.
  • Risk Stratification: The articles highlight the importance of risk stratification in determining the appropriate treatment approach. They all agree that patient-specific factors, such as the severity of ischemia, wound extent, and presence of infection, should guide the choice of revascularization strategy.
  • Multidisciplinary Approach: The need for a multidisciplinary approach to managing PAD and CLI is a common theme. The articles stress the importance of collaboration among vascular surgeons, interventional radiologists, podiatrists, and other specialists to optimize patient care.

In summary, while all three articles agree on the importance of revascularization, risk stratification, and a multidisciplinary approach, they differ in their specific criteria for revascularization, focus on patient populations, and recommendations for specific procedures. These differences highlight the need for individualized treatment plans based on patient-specific factors and the importance of a comprehensive approach to managing PAD and CLI.

References

1.        Patel MR, Spertus JA, Brindis RG, et al. ACCF Proposed Method for Evaluating the Appropriateness of Cardiovascular Imaging. J Am Coll Cardiol. 2005;46(8):1606-1613. doi:10.1016/j.jacc.2005.08.030

2.        Hendel RC, Lindsay BD, Allen JM, et al. ACC Appropriate Use Criteria Methodology: 2018 Update. J Am Coll Cardiol. 2018;71(8):935-948. doi:10.1016/j.jacc.2018.01.007

3.        Hendel RC, Patel MR, Allen JM, et al. Appropriate Use of Cardiovascular Technology: 2013 ACCF appropriate use criteria methodology update. J Am Coll Cardiol. 2013;61(12):1305-1317. doi:10.1016/j.jacc.2013.01.025

4.        Fitch Kathryn, Bernstein SJ, Aguilar MD, et al. The RAND/UCLA Appropriateness Method User’s Manual. RAND.; 2001. Accessed October 8, 2024. https://www.rand.org/pubs/monograph_reports/MR1269.html

5.        Bonow RO, Douglas PS, Buxton AE, et al. ACCF/AHA Methodology for the Development of Quality Measures for Cardiovascular Technology. J Am Coll Cardiol. 2011;58(14):1517-1538. doi:10.1016/j.jacc.2011.07.007

6.        Bailey SR, Beckman JA, Dao TD, et al. ACC/AHA/SCAI/SIR/SVM 2018 Appropriate Use Criteria for Peripheral Artery Intervention. J Am Coll Cardiol. 2019;73(2):214-237. doi:10.1016/j.jacc.2018.10.002

7.        Gornik HL, Aronow HD, Goodney PP, et al. 2024 ACC/AHA/AACVPR/APMA/ABC/SCAI/SVM/SVN/SVS/SIR/VESS Guideline for the Management of Lower Extremity Peripheral Artery Disease. J Am Coll Cardiol. 2024;83(24):2497-2604. doi:10.1016/j.jacc.2024.02.013

8.        Woo K, Siracuse JJ, Klingbeil K, et al. Society for Vascular Surgery appropriate use criteria for management of intermittent claudication. J Vasc Surg. 2022;76(1):3-22.e1. doi:10.1016/j.jvs.2022.04.012

9.        Conte MS, Aulivola B, Barshes NR, et al. Society for Vascular Surgery Clinical Practice Guideline on the management of intermittent claudication: Focused update. J Vasc Surg. 2025;82(2):303-326.e11. doi:10.1016/j.jvs.2025.04.041

10.      Farber A, Menard MT, Conte MS, et al. Surgery or Endovascular Therapy for Chronic Limb-Threatening Ischemia. New England Journal of Medicine. 2022;387(25):2305-2316. doi:10.1056/NEJMoa2207899

11.      Mills JL, Conte MS, Armstrong DG, et al. The Society for Vascular Surgery Lower Extremity Threatened Limb Classification System: Risk stratification based on Wound, Ischemia, and foot Infection (WIfI). J Vasc Surg. 2014;59(1):220-234.e2. doi:10.1016/j.jvs.2013.08.003

12.      Wanhainen A, Van Herzeele I, Bastos Goncalves F, et al. Editor’s Choice -- European Society for Vascular Surgery (ESVS) 2024 Clinical Practice Guidelines on the Management of Abdominal Aorto-Iliac Artery Aneurysms. European Journal of Vascular and Endovascular Surgery. 2024;67(2):192-331. doi:10.1016/j.ejvs.2023.11.002

13.      Lawrence PF, Harlander-Locke MP, Oderich GS, et al. The current management of isolated degenerative femoral artery aneurysms is too aggressive for their natural history. J Vasc Surg. 2014;59(2):343-349. doi:10.1016/j.jvs.2013.08.090

14.     Zierler RE, Jordan WD, Lal BK, et al. The Society for Vascular Surgery practice guidelines on follow-up after vascular surgery arterial procedures. J Vasc Surg. 2018;68(1):256-284. doi:10.1016/j.jvs.2018.04.018

15.      Abu Dabrh AM, Mohammed K, Farah W, et al. Systematic review and meta-analysis of duplex ultrasound surveillance for infrainguinal vein bypass grafts. J Vasc Surg. 2017;66(6):1885-1891. doi:10.1016/j.jvs.2017.06.113

Coding Section

CPT Code Description
 

33210

Insertion or replacement of temporary transvenous single chamber cardiac electrode or pacemaker catheter (separate procedure)

 

33211

Insertion or replacement of temporary transvenous dual chamber pacing electrodes (separate procedure)

 

33214 

Upgrade of implanted pacemaker system, conversion of single chamber system to dual chamber system (includes removal of previously placed pulse generator, testing of existing lead, insertion of new lead, insertion of new pulse generator)

 

33215

Repositioning of previously implanted transvenous pacemaker or implantable defibrillator (right atrial or right ventricular) electrode

 

33216

Insertion of a single transvenous electrode, permanent pacemaker or implantable defibrillator

 

33217

Insertion of 2 transvenous electrodes, permanent pacemaker or implantable defibrillator

 

33218

Repair of single transvenous electrode, permanent pacemaker or implantable defibrillator

 

33220

Repair of 2 transvenous electrodes for permanent pacemaker or implantable defibrillator

 

33223

Relocation of skin pocket for implantable defibrillator

 

33230

Insertion of implantable defibrillator pulse generator only; with existing dual leads

 

33231

Insertion of implantable defibrillator pulse generator only; with existing multiple leads

 

33240

Insertion of implantable defibrillator pulse generator only; with existing single lead

 

33241

Removal of implantable defibrillator pulse generator only

 

33244

Removal of single or dual chamber implantable defibrillator electrode(s); by transvenous extraction

 

33249

Insertion or replacement of permanent implantable defibrillator system, with transvenous lead(s), single or dual chamber

 

33262

Removal of implantable defibrillator pulse generator with replacement of implantable defibrillator pulse generator; single lead system

 

33263

Removal of implantable defibrillator pulse generator with replacement of implantable defibrillator pulse generator; dual lead system

 

33264

Removal of implantable defibrillator pulse generator with replacement of implantable defibrillator pulse generator; multiple lead system  

 

33270

Insertion or replacement of permanent subcutaneous implantable defibrillator system, with subcutaneous electrode, including defibrillation threshold evaluation, induction of arrhythmia, evaluation of sensing for arrhythmia termination, and programming or reprogramming of sensing or therapeutic parameters, when performed

 

33271

Insertion of subcutaneous implantable defibrillator electrode

 

33272

Removal of subcutaneous implantable defibrillator electrode

 

33273

Repositioning of previously implanted subcutaneous implantable defibrillator electrode

 

93640

Electrophysiologic evaluation of single or dual chamber pacing cardioverter-defibrillator leads including defibrillation threshold evaluation (induction of arrhythmia, evaluation of sensing and pacing for arrhythmia termination) at time of initial implantation or replacement

 

93641

Electrophysiologic evaluation of single or dual chamber pacing cardioverter-defibrillator leads including defibrillation threshold evaluation (induction of arrhythmia, evaluation of sensing and pacing for arrhythmia termination) at time of initial implantation or replacement; with testing of single or dual chamber pacing cardioverter-defibrillator pulse generator

 

93644

Electrophysiologic evaluation of subcutaneous implantable defibrillator (includes defibrillation threshold evaluation, induction of arrhythmia, evaluation of sensing for arrhythmia termination, and programming or reprogramming of sensing or therapeutic parameters)

 

Procedure and diagnosis codes on Medical Policy documents are included only as a general reference tool for each Policy. They may not be all-inclusive.

This medical policy was developed through consideration of peer-reviewed medical literature generally recognized by the relevant medical community, U.S. FDA approval status, nationally accepted standards of medical practice and accepted standards of medical practice in this community, and other nonaffiliated technology evaluation centers, reference to federal regulations, other plan medical policies and accredited national guidelines.

"Current Procedural Terminology © American Medical Association. All Rights Reserved" 

History From 2026 Forward

11/01/2026 New Policy
Complementary Content
${loading}